Energy Performance Certificate

FLAT 2/2 , 1 GLENMORE PLACE , GLASGOW, G42 0EA

EPC Report

Energy rating

Current: 83 B | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 B Current: 83 B 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 76 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 77 Potential: 77
Field Value
Id 4469821
BUILDING REFERENCE NUMBER 1000753402
OSG REFERENCE NUMBER 906700426177
ADDRESS1 FLAT 2/2
ADDRESS2 1 GLENMORE PLACE
ADDRESS3 GLASGOW
POSTCODE G42 0EA
INSPECTION DATE 2016-09-14
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2016-09-14
ENERGY CONSUMPTION CURRENT 203.00
TOTAL FLOOR AREA 49
3 YR ENERGY COST CURRENT 930.0000
3 YR ENERGY SAVINGS POTENTIAL 84.0000
CURRENT ENERGY EFFICIENCY 83
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 85
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 76
CURRENT ENVIRONMENTAL RATING C
ENVIRONMENT IMPACT POTENTIAL 77
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 34.00
IMPROVEMENTS Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 28; Energy Rating after improvement: B 85; Environmental Rating after improvement: C 77; Green Deal Eligible: N |
WALL DESCRIPTION Cavity wall, as built, insulated (assumed)
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 1.70
CO2 EMISSIONS POTENTIAL 0.10
HEATING COST CURRENT 297.0000
HEATING COST POTENTIAL 321.0000
HOT WATER COST CURRENT 396.00
HOT WATER COST POTENTIAL 396.00
LIGHTING COST CURRENT 237.00
LIGHTING COST POTENTIAL 129.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES
SPACE HEATING DEMAND 1052
WATER HEATING DEMAND 1698
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND 2008 onwards
FLOOR HEIGHT 2.35
DATA ZONE S01003142 (Toryglen and Oatlands)
ENERGY CONSUMPTION POTENTIAL 196.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 1
LOW ENERGY LIGHTING 14.00
FLOOR LEVEL mid floor
FLAT TOP STOREY 02
GLAZED AREA 1
NUMBER HABITABLE ROOMS 3
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 3
LOCAL AUTHORITY LABEL Glasgow City
MAINS GAS FLAG
MAIN HEATING CATEGORY electric storage heaters
MAIN FUEL electricity (not community)
MAIN HEATING CONTROLS 2402
MECHANICAL VENTILATION natural
ENERGY TARIFF dual
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE owner-occupied
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH 9.7
CONSTITUENCY 00QSMH
CONSTITUENCY LABEL Southside Central
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01010018 (Toryglen and Oatlands - 03)
CREATED AT 14/09/2016 15:15:07
REPORT REFERENCE NUMBER 0140-2234-0010-9596-0785
Source file Q3 2016.csv
Address display FLAT 2/2 , 1 GLENMORE PLACE , GLASGOW
Nation scotland