Energy Performance Certificate
FLAT B , 271 KELVINDALE ROAD , GLASGOW, G12 0QU
Energy rating
Current: 59 D | Potential: 76 C
Environmental impact (CO₂)
Current: 47
| Potential: 59
| Field | Value |
|---|---|
| Id | 3702712 |
| BUILDING REFERENCE NUMBER | 1000880440 |
| OSG REFERENCE NUMBER | 906700062917 |
| ADDRESS1 | FLAT B |
| ADDRESS2 | 271 KELVINDALE ROAD |
| ADDRESS3 | GLASGOW |
| POSTCODE | G12 0QU |
| INSPECTION DATE | 2017-03-22 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2017-03-26 |
| ENERGY CONSUMPTION CURRENT | 449.00 |
| TOTAL FLOOR AREA | 54 |
| 3 YR ENERGY COST CURRENT | 2472.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 999.0000 |
| CURRENT ENERGY EFFICIENCY | 59 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 76 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 47 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 59 |
| POTENTIAL ENVIRONMENTAL RATING | D |
| CO2 EMISS CURR PER FLOOR AREA | 76.00 |
| IMPROVEMENTS | Description: Add additional 80 mm jacket to hot water cylinder; Indicative Cost: £15 - £30; Typical Saving: 21; Energy Rating after improvement: D 65; Environmental Rating after improvement: E 54; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £40; Typical Saving: 32; Energy Rating after improvement: D 67; Environmental Rating after improvement: E 54; Green Deal Eligible: N | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 94; Energy Rating after improvement: D 64; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: High heat retention storage heaters and dual immersion cylinder; Indicative Cost: £1,200 - £1,800; Typical Saving: 185; Energy Rating after improvement: C 76; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, as built, insulated (assumed) | Solid brick, as built, insulated (assumed) |
| WALL ENERGY EFF | Good | Good |
| WALL ENV EFF | Good | Good |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | Suspended, limited insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Room heaters, electric |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | No low energy lighting |
| LIGHTING ENERGY EFF | Very Poor |
| LIGHTING ENV EFF | Very Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.10 |
| CO2 EMISSIONS POTENTIAL | 1.10 |
| HEATING COST CURRENT | 1446.0000 |
| HEATING COST POTENTIAL | 933.0000 |
| HOT WATER COST CURRENT | 756.00 |
| HOT WATER COST POTENTIAL | 405.00 |
| LIGHTING COST CURRENT | 270.00 |
| LIGHTING COST POTENTIAL | 135.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5460 |
| WATER HEATING DEMAND | 1868 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1992-1998 |
| FLOOR HEIGHT | 2.36 |
| DATA ZONE | S01003589 (Kelvindale) |
| ENERGY CONSUMPTION POTENTIAL | 335.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | ground floor |
| FLAT TOP STOREY | 00 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric storage heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2401 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 10.62 |
| CONSTITUENCY | 00QSMQ |
| CONSTITUENCY LABEL | Maryhill/Kelvin |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Detached |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010367 (Kelvindale - 05) |
| CREATED AT | 26/03/2017 10:18:58 |
| REPORT REFERENCE NUMBER | 0140-2002-4070-9823-4875 |
| Source file | Q1 2017.csv |
| Address display | FLAT B , 271 KELVINDALE ROAD , GLASGOW |
| Nation | scotland |