Energy Performance Certificate
292 MUIRFIELD DRIVE , GLENROTHES, KY6 2PZ
Energy rating
Current: 40 E | Potential: 64 D
Environmental impact (CO₂)
Current: 50
| Potential: 71
| Field | Value |
|---|---|
| Id | 3926378 |
| BUILDING REFERENCE NUMBER | 1001973839 |
| OSG REFERENCE NUMBER | 320033637 |
| ADDRESS1 | 292 MUIRFIELD DRIVE |
| ADDRESS2 | — |
| ADDRESS3 | GLENROTHES |
| POSTCODE | KY6 2PZ |
| INSPECTION DATE | 2023-02-02 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-02-09 |
| ENERGY CONSUMPTION CURRENT | 423.00 |
| TOTAL FLOOR AREA | 70 |
| 3 YR ENERGY COST CURRENT | 6894.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1317.0000 |
| CURRENT ENERGY EFFICIENCY | 40 |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY EFFICIENCY | 64 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 50 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 71 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 72.00 |
| IMPROVEMENTS | Description: High performance external doors; Indicative Cost: £1,000; Typical Saving: 82; Energy Rating after improvement: E 52; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 152; Energy Rating after improvement: E 49; Environmental Rating after improvement: D 57; Green Deal Eligible: Y | Description: Heat recovery system for mixer showers; Indicative Cost: £585 - £725; Typical Saving: 40; Energy Rating after improvement: E 50; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 395; Energy Rating after improvement: D 64; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | Description: Floor insulation (solid floor); Indicative Cost: £4,000 - £6,000; Typical Saving: 166; Energy Rating after improvement: E 44; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity |
| WALL ENERGY EFF | Average |
| WALL ENV EFF | Average |
| ROOF DESCRIPTION | Pitched, 300 mm loft insulation |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | No thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 88% of fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.00 |
| CO2 EMISSIONS POTENTIAL | 1.90 |
| HEATING COST CURRENT | 5541.0000 |
| HEATING COST POTENTIAL | 4812.0000 |
| HOT WATER COST CURRENT | 1095.00 |
| HOT WATER COST POTENTIAL | 507.00 |
| LIGHTING COST CURRENT | 258.00 |
| LIGHTING COST POTENTIAL | 258.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 7478 |
| WATER HEATING DEMAND | 1827 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1965-1975 |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01002878 (Leslie and Newcastle) |
| ENERGY CONSUMPTION POTENTIAL | 262.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 88.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 1 |
| LOCAL AUTHORITY LABEL | Fife |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | electric underfloor heating |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2701 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | dual |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QRMP |
| CONSTITUENCY LABEL | Glenrothes West and Kinglassie |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009551 (Newcastle East) |
| CREATED AT | 09/02/2023 14:21:13 |
| REPORT REFERENCE NUMBER | 0129-1019-3202-8337-7204 |
| Source file | Q1 2023.csv |
| Address display | 292 MUIRFIELD DRIVE , GLENROTHES |
| Nation | scotland |