Energy Performance Certificate
49 MILQUHANZIE WAY , CRIEFF, PH7 3FR
Energy rating
Current: 81 B | Potential: 90 B
Environmental impact (CO₂)
Current: 96
| Potential: 98
| Field | Value |
|---|---|
| Id | 4460549 |
| BUILDING REFERENCE NUMBER | 1236519211 |
| OSG REFERENCE NUMBER | 124116829 |
| ADDRESS1 | 49 MILQUHANZIE WAY |
| ADDRESS2 | — |
| ADDRESS3 | CRIEFF |
| POSTCODE | PH7 3FR |
| INSPECTION DATE | 2025-06-13 |
| TYPE OF ASSESSMENT | — |
| LODGEMENT DATE | 2025-06-13 |
| ENERGY CONSUMPTION CURRENT | 48.00 |
| TOTAL FLOOR AREA | 107 |
| 3 YR ENERGY COST CURRENT | 2601.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 99.0000 |
| CURRENT ENERGY EFFICIENCY | 81 |
| CURRENT ENERGY RATING | B |
| POTENTIAL ENERGY EFFICIENCY | 90 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 96 |
| CURRENT ENVIRONMENTAL RATING | A |
| ENVIRONMENT IMPACT POTENTIAL | 98 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 4.60 |
| IMPROVEMENTS | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 288; Energy Rating after improvement: B 90; Environmental Rating after improvement: A 98; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 33; Energy Rating after improvement: B 82; Environmental Rating after improvement: A 96; Green Deal Eligible: N | |
| WALL DESCRIPTION | Average thermal transmittance 0.16 W/m²K |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Average thermal transmittance 0.11 W/m²K |
| ROOF ENERGY EFF | Very Good |
| ROOF ENV EFF | Very Good |
| FLOOR DESCRIPTION | Average thermal transmittance 0.11 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | — |
| WINDOWS ENERGY EFF | — |
| WINDOWS ENV EFF | — |
| MAINHEAT DESCRIPTION | Air source heat pump, radiators, electric |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Time and temperature zone control |
| MAINHEATC ENERGY EFF | Very Good |
| MAINHEATC ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Excelent lighting efficiency |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | Air permeability [AP50] = 3.1 m³/h.m² (as tested) |
| AIR TIGHTNESS ENERGY EFF | Good |
| AIR TIGHTNESS ENV EFF | Good |
| CO2 EMISSIONS CURRENT | 0.50 |
| CO2 EMISSIONS POTENTIAL | 0.20 |
| HEATING COST CURRENT | 1407.0000 |
| HEATING COST POTENTIAL | 1473.0000 |
| HOT WATER COST CURRENT | 1017.00 |
| HOT WATER COST POTENTIAL | 852.00 |
| LIGHTING COST CURRENT | 177.00 |
| LIGHTING COST POTENTIAL | 177.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Air source heat pump | |
| SPACE HEATING DEMAND | — |
| WATER HEATING DEMAND | — |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | — |
| FLOOR HEIGHT | 2.42 |
| DATA ZONE | — |
| ENERGY CONSUMPTION POTENTIAL | 32.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 0 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 0 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 0 |
| LOCAL AUTHORITY LABEL | — |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | heat pump with radiators or underfloor heating |
| MAIN FUEL | Electricity: electricity, unspecified tariff |
| MAIN HEATING CONTROLS | 2207 |
| MECHANICAL VENTILATION | — |
| ENERGY TARIFF | — |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| TENURE | unknown |
| TRANSACTION TYPE | new dwelling |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | — |
| CONSTITUENCY LABEL | — |
| WIND TURBINE COUNT | — |
| BUILT FORM | Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | — |
| CREATED AT | 13/06/2025 11:39:29 |
| REPORT REFERENCE NUMBER | 0122-3197-1663-2195-7511 |
| Source file | Q2 2025.csv |
| Address display | 49 MILQUHANZIE WAY , CRIEFF |
| Nation | scotland |