Energy Performance Certificate

4 STEWARDS WAY , RENFREW, PA4 8GA

EPC Report

Energy rating

Current: 89 B | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 B Current: 89 B 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 91 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 91 Current: 91 93 Potential: 93
Field Value
Id 4357858
BUILDING REFERENCE NUMBER 1236104111
OSG REFERENCE NUMBER 123118992
ADDRESS1 4 STEWARDS WAY
ADDRESS2
ADDRESS3 RENFREW
POSTCODE PA4 8GA
INSPECTION DATE 2023-06-07
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2023-06-07
ENERGY CONSUMPTION CURRENT 58.00
TOTAL FLOOR AREA 102
3 YR ENERGY COST CURRENT 2520.0000
3 YR ENERGY SAVINGS POTENTIAL 234.0000
CURRENT ENERGY EFFICIENCY 89
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 90
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 91
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 93
POTENTIAL ENVIRONMENTAL RATING A
CO2 EMISS CURR PER FLOOR AREA 10.00
IMPROVEMENTS Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 79; Energy Rating after improvement: B 90; Environmental Rating after improvement: A 93; Green Deal Eligible: N |
WALL DESCRIPTION Average thermal transmittance 0.22 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.11 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 5.0 m³/h.m² (assumed)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 1.10
CO2 EMISSIONS POTENTIAL 0.20
HEATING COST CURRENT 1347.0000
HEATING COST POTENTIAL 1347.0000
HOT WATER COST CURRENT 687.00
HOT WATER COST POTENTIAL 453.00
LIGHTING COST CURRENT 486.00
LIGHTING COST POTENTIAL 486.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES Description: Solar photovoltaics |
SPACE HEATING DEMAND 2711
WATER HEATING DEMAND 2079
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT 2.38
DATA ZONE
ENERGY CONSUMPTION POTENTIAL 48.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL Gas: mains gas
MAIN HEATING CONTROLS 2110
MECHANICAL VENTILATION
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Peak Power: 1.00499999; Orientation: South West; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; |
SOLAR WATER HEATING FLAG
TENURE owner-occupied
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY
CONSTITUENCY LABEL
WIND TURBINE COUNT 0
BUILT FORM End-Terrace
PROPERTY TYPE House
DATA ZONE 2011
CREATED AT 07/06/2023 10:25:24
REPORT REFERENCE NUMBER 0112-3143-1663-2007-3161
Source file Q2 2023.csv
Address display 4 STEWARDS WAY , RENFREW
Nation scotland