Energy Performance Certificate

Flat 3/2 , 17 Park Quadrant , Glasgow, G3 6BF

EPC Report

Energy rating

Current: 88 B | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 88 B Current: 88 B 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 89 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 89 Current: 89 89 Potential: 89
Field Value
Id 3852954
BUILDING REFERENCE NUMBER 1235381036
OSG REFERENCE NUMBER
ADDRESS1 Flat 3/2
ADDRESS2 17 Park Quadrant
ADDRESS3 Glasgow
POSTCODE G3 6BF
INSPECTION DATE 2021-02-25
TYPE OF ASSESSMENT SAP, new dwelling
LODGEMENT DATE 2021-02-25
ENERGY CONSUMPTION CURRENT 64.00
TOTAL FLOOR AREA 113
3 YR ENERGY COST CURRENT 1233.0000
3 YR ENERGY SAVINGS POTENTIAL 0.0000
CURRENT ENERGY EFFICIENCY 88
CURRENT ENERGY RATING B
POTENTIAL ENERGY EFFICIENCY 88
POTENTIAL ENERGY RATING B
ENVIRONMENT IMPACT CURRENT 89
CURRENT ENVIRONMENTAL RATING B
ENVIRONMENT IMPACT POTENTIAL 89
POTENTIAL ENVIRONMENTAL RATING B
CO2 EMISS CURR PER FLOOR AREA 11.00
IMPROVEMENTS
WALL DESCRIPTION Average thermal transmittance 0.13 W/m²K
WALL ENERGY EFF Very Good
WALL ENV EFF Very Good
ROOF DESCRIPTION (other premises above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system, waste water heat recovery
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
AIR TIGHTNESS DESCRIPTION Air permeability 4.0 m³/h.m² (as tested)
AIR TIGHTNESS ENERGY EFF Good
AIR TIGHTNESS ENV EFF Good
CO2 EMISSIONS CURRENT 1.30
CO2 EMISSIONS POTENTIAL 0.00
HEATING COST CURRENT 705.0000
HEATING COST POTENTIAL 705.0000
HOT WATER COST CURRENT 270.00
HOT WATER COST POTENTIAL 270.00
LIGHTING COST CURRENT 258.00
LIGHTING COST POTENTIAL 258.00
ALTERNATIVE IMPROVEMENTS
LZC ENERGY SOURCES Description: Solar photovoltaics |
SPACE HEATING DEMAND 2975
WATER HEATING DEMAND 2311
IMPACT LOFT INSULATION 0
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION 0
ADDENDUM TEXT
CONSTRUCTION AGE BAND
FLOOR HEIGHT
DATA ZONE
ENERGY CONSUMPTION POTENTIAL 64.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
LOW ENERGY LIGHTING 100.00
FLOOR LEVEL mid floor
FLAT TOP STOREY
GLAZED AREA 0
NUMBER HABITABLE ROOMS 0
HEAT LOSS CORRIDOOR
NUMBER HEATED ROOMS 0
LOCAL AUTHORITY LABEL
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL Gas: mains gas
MAIN HEATING CONTROLS 2110
MECHANICAL VENTILATION mechanical, supply and extract
ENERGY TARIFF
MULTI GLAZE PROPORTION 0
GLAZED TYPE
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Peak Power: 0.5; Orientation: South; Pitch: 30 degrees; Overshading: none or very little; Connection: connected to dwelling’s electricity meter; |
SOLAR WATER HEATING FLAG
TENURE owner-occupied
TRANSACTION TYPE new dwelling
UNHEATED CORRIDOR LENGTH
CONSTITUENCY
CONSTITUENCY LABEL
WIND TURBINE COUNT 0
BUILT FORM Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01010290 (Woodlands - 02)
CREATED AT 25/02/2021 16:55:23
REPORT REFERENCE NUMBER 0102-3615-3523-2829-6331
Source file Q1 2021.csv
Address display Flat 3/2 , 17 Park Quadrant , Glasgow
Nation scotland