Energy Performance Certificate

3F2 , 41 MCDONALD ROAD , EDINBURGH, EH7 4LY

EPC Report

Energy rating

Current: 48 E | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 43 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 78 Potential: 78
Field Value
Id 4560863
BUILDING REFERENCE NUMBER 1000430000
OSG REFERENCE NUMBER 906348998
ADDRESS1 3F2
ADDRESS2 41 MCDONALD ROAD
ADDRESS3 EDINBURGH
POSTCODE EH7 4LY
INSPECTION DATE 2019-09-17
TYPE OF ASSESSMENT RdSAP, existing dwelling
LODGEMENT DATE 2019-09-17
ENERGY CONSUMPTION CURRENT 508.00
TOTAL FLOOR AREA 47
3 YR ENERGY COST CURRENT 2694.0000
3 YR ENERGY SAVINGS POTENTIAL 1479.0000
CURRENT ENERGY EFFICIENCY 48
CURRENT ENERGY RATING E
POTENTIAL ENERGY EFFICIENCY 76
POTENTIAL ENERGY RATING C
ENVIRONMENT IMPACT CURRENT 43
CURRENT ENVIRONMENTAL RATING E
ENVIRONMENT IMPACT POTENTIAL 78
POTENTIAL ENVIRONMENTAL RATING C
CO2 EMISS CURR PER FLOOR AREA 90.00
IMPROVEMENTS Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 127; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 78; Green Deal Eligible: Y | Description: Increase loft insulation to 270 mm; Indicative Cost: £100 - £350; Typical Saving: 248; Energy Rating after improvement: D 62; Environmental Rating after improvement: D 59; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 101; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 67; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £10; Typical Saving: 18; Energy Rating after improvement: D 68; Environmental Rating after improvement: D 68; Green Deal Eligible: N |
WALL DESCRIPTION Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, no insulation (assumed)
WALL ENERGY EFF Poor | Poor
WALL ENV EFF Poor | Poor
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Description: Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
AIR TIGHTNESS DESCRIPTION
AIR TIGHTNESS ENERGY EFF
AIR TIGHTNESS ENV EFF
CO2 EMISSIONS CURRENT 4.20
CO2 EMISSIONS POTENTIAL 2.60
HEATING COST CURRENT 1692.0000
HEATING COST POTENTIAL 609.0000
HOT WATER COST CURRENT 828.00
HOT WATER COST POTENTIAL 489.00
LIGHTING COST CURRENT 174.00
LIGHTING COST POTENTIAL 117.00
ALTERNATIVE IMPROVEMENTS Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP |
LZC ENERGY SOURCES
SPACE HEATING DEMAND 8295
WATER HEATING DEMAND 4823
IMPACT LOFT INSULATION -4791
IMPACT CAVITY WALL INSULATION 0
IMPACT SOLID WALL INSULATION -2015
ADDENDUM TEXT
CONSTRUCTION AGE BAND before 1919
FLOOR HEIGHT 2.95
DATA ZONE S01002225 (Broughton)
ENERGY CONSUMPTION POTENTIAL 189.00
EXTENSION COUNT 0
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 2
LOW ENERGY LIGHTING 50.00
FLOOR LEVEL top floor
FLAT TOP STOREY 03
GLAZED AREA 1
NUMBER HABITABLE ROOMS 2
HEAT LOSS CORRIDOOR unheated corridor
NUMBER HEATED ROOMS 2
LOCAL AUTHORITY LABEL Edinburgh City
MAINS GAS FLAG
MAIN HEATING CATEGORY boiler with radiators or underfloor heating
MAIN FUEL mains gas (not community)
MAIN HEATING CONTROLS 2107
MECHANICAL VENTILATION natural
ENERGY TARIFF Single
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
NUMBER OPEN FIREPLACES 0
PHOTO SUPPLY Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); |
SOLAR WATER HEATING FLAG N
TENURE rented (private)
TRANSACTION TYPE rental
UNHEATED CORRIDOR LENGTH 6
CONSTITUENCY 00QPMM
CONSTITUENCY LABEL Leith Walk
WIND TURBINE COUNT 0
BUILT FORM Enclosed Mid-Terrace
PROPERTY TYPE Flat
DATA ZONE 2011 S01008843 (Broughton South - 04)
CREATED AT 17/09/2019 21:01:00
REPORT REFERENCE NUMBER 0100-2003-0010-9391-9455
Source file Q3 2019.csv
Address display 3F2 , 41 MCDONALD ROAD , EDINBURGH
Nation scotland