Energy Performance Certificate
FLAT 1/1 , 138 PARK ROAD , GLASGOW, G4 9HB
Energy rating
Current: 27 F | Potential: 72 C
Environmental impact (CO₂)
Current: 68
| Potential: 76
| Field | Value |
|---|---|
| Id | 5164707 |
| BUILDING REFERENCE NUMBER | 1000877037 |
| OSG REFERENCE NUMBER | 906700090366 |
| ADDRESS1 | FLAT 1/1 |
| ADDRESS2 | 138 PARK ROAD |
| ADDRESS3 | GLASGOW |
| POSTCODE | G4 9HB |
| INSPECTION DATE | 2025-10-08 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2025-10-08 |
| ENERGY CONSUMPTION CURRENT | 387.00 |
| TOTAL FLOOR AREA | 40 |
| 3 YR ENERGY COST CURRENT | 6720.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 4803.0000 |
| CURRENT ENERGY EFFICIENCY | 27 |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY EFFICIENCY | 72 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 68 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 76 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 50.00 |
| IMPROVEMENTS | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £4,500 - £6,000; Typical Saving: 71; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 76; Green Deal Eligible: N | Description: Draughtproofing; Indicative Cost: £150 - £250; Typical Saving: 114; Energy Rating after improvement: F 38; Environmental Rating after improvement: C 76; Green Deal Eligible: N | Description: Change heating to gas condensing boiler; Indicative Cost: £3,500 - £10,000; Typical Saving: 1076; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 72; Green Deal Eligible: N | Description: Internal or external wall insulation; Indicative Cost: £7,500 - £11,000; Typical Saving: 341; Energy Rating after improvement: F 35; Environmental Rating after improvement: C 74; Green Deal Eligible: N | |
| WALL DESCRIPTION | Sandstone, as built, no insulation (assumed) | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Poor | Average |
| WALL ENV EFF | Poor | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | — |
| WINDOWS ENERGY EFF | — |
| WINDOWS ENV EFF | — |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Very Good |
| MAINHEATCONT DESCRIPTION | Appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Very Good |
| LIGHTING DESCRIPTION | Below average lighting efficiency |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.00 |
| CO2 EMISSIONS POTENTIAL | 0.50 |
| HEATING COST CURRENT | 4854.0000 |
| HEATING COST POTENTIAL | 1233.0000 |
| HOT WATER COST CURRENT | 1749.00 |
| HOT WATER COST POTENTIAL | 564.00 |
| LIGHTING COST CURRENT | 117.00 |
| LIGHTING COST POTENTIAL | 120.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5168.77 |
| WATER HEATING DEMAND | 2049.21 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | — |
| DATA ZONE | S01003487 (Woodlands) |
| ENERGY CONSUMPTION POTENTIAL | 209.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 0 |
| LOW ENERGY FIXED LIGHT COUNT | 0 |
| LOW ENERGY LIGHTING | 0.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 0 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Glasgow City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | — |
| MAIN FUEL | — |
| MAIN HEATING CONTROLS | — |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | — |
| NUMBER OPEN FIREPLACES | — |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 6.2 |
| CONSTITUENCY | 00QSML |
| CONSTITUENCY LABEL | Hillhead |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | — |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01010291 (Woodlands - 03) |
| CREATED AT | 08/10/2025 15:11:54 |
| REPORT REFERENCE NUMBER | 0087-1908-3200-0875-7204 |
| Source file | Q4 2025.csv |
| Address display | FLAT 1/1 , 138 PARK ROAD , GLASGOW |
| Nation | scotland |