Energy Performance Certificate
118 GLENACRE ROAD , CARBRAIN , GLASGOW, G67 2PE
Energy rating
Current: 38 F | Potential: 79 C
Environmental impact (CO₂)
Current: 45
| Potential: 79
| Field | Value |
|---|---|
| Id | 4323140 |
| BUILDING REFERENCE NUMBER | 1000477372 |
| OSG REFERENCE NUMBER | 118025565 |
| ADDRESS1 | 118 GLENACRE ROAD |
| ADDRESS2 | CARBRAIN |
| ADDRESS3 | GLASGOW |
| POSTCODE | G67 2PE |
| INSPECTION DATE | 2023-04-06 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2023-04-27 |
| ENERGY CONSUMPTION CURRENT | 417.00 |
| TOTAL FLOOR AREA | 81 |
| 3 YR ENERGY COST CURRENT | 12123.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 8721.0000 |
| CURRENT ENERGY EFFICIENCY | 38 |
| CURRENT ENERGY RATING | F |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY RATING | C |
| ENVIRONMENT IMPACT CURRENT | 45 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| POTENTIAL ENVIRONMENTAL RATING | C |
| CO2 EMISS CURR PER FLOOR AREA | 70.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £30; Typical Saving: 64; Energy Rating after improvement: D 57; Environmental Rating after improvement: D 61; Green Deal Eligible: N | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 158; Energy Rating after improvement: E 40; Environmental Rating after improvement: E 47; Green Deal Eligible: Y | Description: Change heating to gas condensing boiler; Indicative Cost: £3,000 - £7,000; Typical Saving: 1743; Energy Rating after improvement: C 79; Environmental Rating after improvement: C 79; Green Deal Eligible: Y | Description: Insulate hot water cylinder with 80 mm jacket; Indicative Cost: £15 - £30; Typical Saving: 943; Energy Rating after improvement: D 55; Environmental Rating after improvement: D 60; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Cavity wall, filled cavity | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Average | Average |
| WALL ENV EFF | Average | Average |
| ROOF DESCRIPTION | Pitched, 270 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, electric |
| MAINHEAT ENERGY EFF | Very Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Appliance thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 14% of fixed outlets |
| LIGHTING ENERGY EFF | Poor |
| LIGHTING ENV EFF | Poor |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 5.70 |
| CO2 EMISSIONS POTENTIAL | 3.60 |
| HEATING COST CURRENT | 4638.0000 |
| HEATING COST POTENTIAL | 2127.0000 |
| HOT WATER COST CURRENT | 6720.00 |
| HOT WATER COST POTENTIAL | 861.00 |
| LIGHTING COST CURRENT | 765.00 |
| LIGHTING COST POTENTIAL | 414.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Biomass boiler (Exempted Appliance if in Smoke Control Area) | Description: Air or ground source heat pump | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4196 |
| WATER HEATING DEMAND | 6077 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -428 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1950-1964 |
| FLOOR HEIGHT | 2.65 |
| DATA ZONE | S01004874 (Greenfaulds) |
| ENERGY CONSUMPTION POTENTIAL | 151.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 1 |
| LOW ENERGY LIGHTING | 14.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 03 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | North Lanarkshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | room heaters |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2602 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing, unknown install date |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | ECO assessment |
| UNHEATED CORRIDOR LENGTH | 5.36 |
| CONSTITUENCY | 00QZMC |
| CONSTITUENCY LABEL | Cumbernauld South |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01011738 (Greenfaulds - 05) |
| CREATED AT | 27/04/2023 13:25:36 |
| REPORT REFERENCE NUMBER | 0062-1004-7204-3877-7204 |
| Source file | Q2 2023.csv |
| Address display | 118 GLENACRE ROAD , CARBRAIN , GLASGOW |
| Nation | scotland |