Energy Performance Certificate
49 HIGH STREET , NEW DEER , TURRIFF, AB53 6SX
Energy rating
Current: 61 D | Potential: 89 B
Environmental impact (CO₂)
Current: 65
| Potential: 90
| Field | Value |
|---|---|
| Id | 4257076 |
| BUILDING REFERENCE NUMBER | 1001877954 |
| OSG REFERENCE NUMBER | 151081540 |
| ADDRESS1 | 49 HIGH STREET |
| ADDRESS2 | NEW DEER |
| ADDRESS3 | TURRIFF |
| POSTCODE | AB53 6SX |
| INSPECTION DATE | 2021-03-05 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2021-04-07 |
| ENERGY CONSUMPTION CURRENT | 379.00 |
| TOTAL FLOOR AREA | 39 |
| 3 YR ENERGY COST CURRENT | 2706.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 759.0000 |
| CURRENT ENERGY EFFICIENCY | 61 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 89 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 65 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 90 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 64.00 |
| IMPROVEMENTS | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 79; Energy Rating after improvement: C 71; Environmental Rating after improvement: C 74; Green Deal Eligible: Y | Description: High performance external doors; Indicative Cost: £1,000; Typical Saving: 36; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £3,500 - £5,500; Typical Saving: 300; Energy Rating after improvement: B 89; Environmental Rating after improvement: B 90; Green Deal Eligible: Y | Description: Floor insulation (suspended floor); Indicative Cost: £800 - £1,200; Typical Saving: 139; Energy Rating after improvement: D 67; Environmental Rating after improvement: C 71; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Granite or whinstone, with internal insulation |
| WALL ENERGY EFF | Good |
| WALL ENV EFF | Good |
| ROOF DESCRIPTION | Pitched, insulated at rafters |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Air source heat pump, radiators, electric |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer and at least two room thermostats |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.50 |
| CO2 EMISSIONS POTENTIAL | 1.50 |
| HEATING COST CURRENT | 1881.0000 |
| HEATING COST POTENTIAL | 1365.0000 |
| HOT WATER COST CURRENT | 720.00 |
| HOT WATER COST POTENTIAL | 477.00 |
| LIGHTING COST CURRENT | 105.00 |
| LIGHTING COST POTENTIAL | 105.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | Description: Air source heat pump | |
| SPACE HEATING DEMAND | 5440 |
| WATER HEATING DEMAND | 2159 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 2.24 |
| DATA ZONE | S01000493 (Deer and Mormond) |
| ENERGY CONSUMPTION POTENTIAL | 146.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 7 |
| LOW ENERGY LIGHTING | 100.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 2 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 2 |
| LOCAL AUTHORITY LABEL | Aberdeenshire |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | heat pump with radiators or underfloor heating |
| MAIN FUEL | electricity (not community) |
| MAIN HEATING CONTROLS | 2205 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QBMD |
| CONSTITUENCY LABEL | Central Buchan |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Semi-Detached |
| PROPERTY TYPE | Bungalow |
| DATA ZONE 2011 | S01007050 (Deer and Mormond - 01) |
| CREATED AT | 07/04/2021 14:14:38 |
| REPORT REFERENCE NUMBER | 0054-1018-5207-9079-7204 |
| Source file | Q2 2021.csv |
| Address display | 49 HIGH STREET , NEW DEER , TURRIFF |
| Nation | scotland |