Energy Performance Certificate
1F1 , 10 CALEDONIAN PLACE , EDINBURGH, EH11 2AS
Energy rating
Current: 65 D | Potential: 82 B
Environmental impact (CO₂)
Current: 62
| Potential: 84
| Field | Value |
|---|---|
| Id | 3791047 |
| BUILDING REFERENCE NUMBER | 1000098250 |
| OSG REFERENCE NUMBER | 906282593 |
| ADDRESS1 | 1F1 |
| ADDRESS2 | 10 CALEDONIAN PLACE |
| ADDRESS3 | EDINBURGH |
| POSTCODE | EH11 2AS |
| INSPECTION DATE | 2020-02-06 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-02-07 |
| ENERGY CONSUMPTION CURRENT | 276.00 |
| TOTAL FLOOR AREA | 70 |
| 3 YR ENERGY COST CURRENT | 2322.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 1155.0000 |
| CURRENT ENERGY EFFICIENCY | 65 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 82 |
| POTENTIAL ENERGY RATING | B |
| ENVIRONMENT IMPACT CURRENT | 62 |
| CURRENT ENVIRONMENTAL RATING | D |
| ENVIRONMENT IMPACT POTENTIAL | 84 |
| POTENTIAL ENVIRONMENTAL RATING | B |
| CO2 EMISS CURR PER FLOOR AREA | 49.00 |
| IMPROVEMENTS | Description: Increase hot water cylinder insulation; Indicative Cost: £15 - £30; Typical Saving: 42; Energy Rating after improvement: C 72; Environmental Rating after improvement: C 72; Green Deal Eligible: Y | Description: Draughtproofing; Indicative Cost: £80 - £120; Typical Saving: 19; Energy Rating after improvement: C 73; Environmental Rating after improvement: C 73; Green Deal Eligible: Y | Description: Hot water cylinder thermostat; Indicative Cost: £200 - £400; Typical Saving: 26; Energy Rating after improvement: C 75; Environmental Rating after improvement: C 75; Green Deal Eligible: Y | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 30; Energy Rating after improvement: C 76; Environmental Rating after improvement: C 77; Green Deal Eligible: Y | Description: Replace boiler with new condensing boiler; Indicative Cost: £2,200 - £3,000; Typical Saving: 61; Energy Rating after improvement: C 79; Environmental Rating after improvement: C 80; Green Deal Eligible: Y | Description: Low energy lighting for all fixed outlets; Indicative Cost: £15; Typical Saving: 22; Energy Rating after improvement: C 74; Environmental Rating after improvement: C 73; Green Deal Eligible: N | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 121; Energy Rating after improvement: C 70; Environmental Rating after improvement: C 69; Green Deal Eligible: Y | Description: Replace single glazed windows with low-E double glazed windows; Indicative Cost: £3,300 - £6,500; Typical Saving: 63; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, as built, no insulation (assumed) | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Poor | Average |
| WALL ENV EFF | Poor | Average |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Single glazed |
| WINDOWS ENERGY EFF | Very Poor |
| WINDOWS ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in 57% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 3.40 |
| CO2 EMISSIONS POTENTIAL | 2.00 |
| HEATING COST CURRENT | 1290.0000 |
| HEATING COST POTENTIAL | 660.0000 |
| HOT WATER COST CURRENT | 783.00 |
| HOT WATER COST POTENTIAL | 330.00 |
| LIGHTING COST CURRENT | 249.00 |
| LIGHTING COST POTENTIAL | 177.00 |
| ALTERNATIVE IMPROVEMENTS | Description: Micro CHP | |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 5369 |
| WATER HEATING DEMAND | 4290 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -2221 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | before 1919 |
| FLOOR HEIGHT | 3.03 |
| DATA ZONE | S01002068 (Dalry and Fountainbridge) |
| ENERGY CONSUMPTION POTENTIAL | 114.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 7 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 57.00 |
| FLOOR LEVEL | mid floor |
| FLAT TOP STOREY | 01 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Edinburgh City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 0 |
| GLAZED TYPE | not defined |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | rented (private) |
| TRANSACTION TYPE | rental |
| UNHEATED CORRIDOR LENGTH | 6.89 |
| CONSTITUENCY | 00QPMG |
| CONSTITUENCY LABEL | Sighthill/Gorgie |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01008654 (Dalry and Fountainbridge - 04) |
| CREATED AT | 07/02/2020 13:56:45 |
| REPORT REFERENCE NUMBER | 0010-5922-2000-0806-0202 |
| Source file | Q1 2020.csv |
| Address display | 1F1 , 10 CALEDONIAN PLACE , EDINBURGH |
| Nation | scotland |