Energy Performance Certificate
232F CLEPINGTON ROAD , DUNDEE, DD3 8BH
Energy rating
Current: 55 D | Potential: 58 D
Environmental impact (CO₂)
Current: 49
| Potential: 53
| Field | Value |
|---|---|
| Id | 3809074 |
| BUILDING REFERENCE NUMBER | 1001571240 |
| OSG REFERENCE NUMBER | 9059085416 |
| ADDRESS1 | 232F CLEPINGTON ROAD |
| ADDRESS2 | — |
| ADDRESS3 | DUNDEE |
| POSTCODE | DD3 8BH |
| INSPECTION DATE | 2020-03-09 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2020-03-11 |
| ENERGY CONSUMPTION CURRENT | 439.00 |
| TOTAL FLOOR AREA | 60 |
| 3 YR ENERGY COST CURRENT | 2994.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 231.0000 |
| CURRENT ENERGY EFFICIENCY | 55 |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY EFFICIENCY | 58 |
| POTENTIAL ENERGY RATING | D |
| ENVIRONMENT IMPACT CURRENT | 49 |
| CURRENT ENVIRONMENTAL RATING | E |
| ENVIRONMENT IMPACT POTENTIAL | 53 |
| POTENTIAL ENVIRONMENTAL RATING | E |
| CO2 EMISS CURR PER FLOOR AREA | 77.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £20; Typical Saving: 22; Energy Rating after improvement: D 57; Environmental Rating after improvement: E 51; Green Deal Eligible: N | Description: Upgrade heating controls; Indicative Cost: £350 - £450; Typical Saving: 32; Energy Rating after improvement: D 58; Environmental Rating after improvement: E 53; Green Deal Eligible: Y | Description: Internal or external wall insulation; Indicative Cost: £4,000 - £14,000; Typical Saving: 23; Energy Rating after improvement: D 56; Environmental Rating after improvement: E 51; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Sandstone or limestone, with external insulation | Solid brick, as built, partial insulation (assumed) |
| WALL ENERGY EFF | Good | Average |
| WALL ENV EFF | Good | Average |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| FLOOR DESCRIPTION | (another dwelling below) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, TRVs and bypass |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 4.60 |
| CO2 EMISSIONS POTENTIAL | 0.30 |
| HEATING COST CURRENT | 2490.0000 |
| HEATING COST POTENTIAL | 2337.0000 |
| HOT WATER COST CURRENT | 273.00 |
| HOT WATER COST POTENTIAL | 273.00 |
| LIGHTING COST CURRENT | 231.00 |
| LIGHTING COST POTENTIAL | 153.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 11369 |
| WATER HEATING DEMAND | 2068 |
| IMPACT LOFT INSULATION | -6757 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | -479 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 1930-1949 |
| FLOOR HEIGHT | 2.6 |
| DATA ZONE | S01001196 (Hilltown) |
| ENERGY CONSUMPTION POTENTIAL | 407.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| LOW ENERGY LIGHTING | 50.00 |
| FLOOR LEVEL | top floor |
| FLAT TOP STOREY | 02 |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 3 |
| HEAT LOSS CORRIDOOR | unheated corridor |
| NUMBER HEATED ROOMS | 3 |
| LOCAL AUTHORITY LABEL | Dundee City |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2107 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | 5.3 |
| CONSTITUENCY | 00QJMD |
| CONSTITUENCY LABEL | Coldside |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | Flat |
| DATA ZONE 2011 | S01007719 (Hilltown - 06) |
| CREATED AT | 11/03/2020 00:37:59 |
| REPORT REFERENCE NUMBER | 0010-1015-4207-2610-7204 |
| Source file | Q1 2020.csv |
| Address display | 232F CLEPINGTON ROAD , DUNDEE |
| Nation | scotland |