Energy Performance Certificate
41 MCCORMACK PLACE , LARBERT, FK5 4TU
Energy rating
Current: 79 C | Potential: 92 A
Environmental impact (CO₂)
Current: 80
| Potential: 92
| Field | Value |
|---|---|
| Id | 4472569 |
| BUILDING REFERENCE NUMBER | 1001008950 |
| OSG REFERENCE NUMBER | 136077145 |
| ADDRESS1 | 41 MCCORMACK PLACE |
| ADDRESS2 | — |
| ADDRESS3 | LARBERT |
| POSTCODE | FK5 4TU |
| INSPECTION DATE | 2016-06-29 |
| TYPE OF ASSESSMENT | RdSAP, existing dwelling |
| LODGEMENT DATE | 2016-07-04 |
| ENERGY CONSUMPTION CURRENT | 126.00 |
| TOTAL FLOOR AREA | 96 |
| 3 YR ENERGY COST CURRENT | 1668.0000 |
| 3 YR ENERGY SAVINGS POTENTIAL | 261.0000 |
| CURRENT ENERGY EFFICIENCY | 79 |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY EFFICIENCY | 92 |
| POTENTIAL ENERGY RATING | A |
| ENVIRONMENT IMPACT CURRENT | 80 |
| CURRENT ENVIRONMENTAL RATING | C |
| ENVIRONMENT IMPACT POTENTIAL | 92 |
| POTENTIAL ENVIRONMENTAL RATING | A |
| CO2 EMISS CURR PER FLOOR AREA | 22.00 |
| IMPROVEMENTS | Description: Low energy lighting for all fixed outlets; Indicative Cost: £35; Typical Saving: 32; Energy Rating after improvement: B 81; Environmental Rating after improvement: B 81; Green Deal Eligible: N | Description: Solar water heating; Indicative Cost: £4,000 - £6,000; Typical Saving: 54; Energy Rating after improvement: B 82; Environmental Rating after improvement: B 84; Green Deal Eligible: Y | Description: Solar photovoltaic panels, 2.5 kWp; Indicative Cost: £5,000 - £8,000; Typical Saving: 250; Energy Rating after improvement: A 92; Environmental Rating after improvement: A 92; Green Deal Eligible: Y | |
| WALL DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALL ENERGY EFF | Very Good |
| WALL ENV EFF | Very Good |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation | Roof room(s), ceiling insulated |
| ROOF ENERGY EFF | Good | Good |
| ROOF ENV EFF | Good | Good |
| FLOOR DESCRIPTION | Solid, insulated (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Description: Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 42% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| AIR TIGHTNESS DESCRIPTION | — |
| AIR TIGHTNESS ENERGY EFF | — |
| AIR TIGHTNESS ENV EFF | — |
| CO2 EMISSIONS CURRENT | 2.10 |
| CO2 EMISSIONS POTENTIAL | 1.20 |
| HEATING COST CURRENT | 960.0000 |
| HEATING COST POTENTIAL | 999.0000 |
| HOT WATER COST CURRENT | 399.00 |
| HOT WATER COST POTENTIAL | 213.00 |
| LIGHTING COST CURRENT | 309.00 |
| LIGHTING COST POTENTIAL | 195.00 |
| ALTERNATIVE IMPROVEMENTS | — |
| LZC ENERGY SOURCES | — |
| SPACE HEATING DEMAND | 4229 |
| WATER HEATING DEMAND | 2589 |
| IMPACT LOFT INSULATION | 0 |
| IMPACT CAVITY WALL INSULATION | 0 |
| IMPACT SOLID WALL INSULATION | 0 |
| ADDENDUM TEXT | — |
| CONSTRUCTION AGE BAND | 2008 onwards |
| FLOOR HEIGHT | 2.3 |
| DATA ZONE | S01002567 (North Broomage and Inches) |
| ENERGY CONSUMPTION POTENTIAL | 51.00 |
| EXTENSION COUNT | 0 |
| FIXED LIGHTING OUTLETS COUNT | 12 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| LOW ENERGY LIGHTING | 42.00 |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | — |
| GLAZED AREA | 1 |
| NUMBER HABITABLE ROOMS | 4 |
| HEAT LOSS CORRIDOOR | — |
| NUMBER HEATED ROOMS | 4 |
| LOCAL AUTHORITY LABEL | Falkirk |
| MAINS GAS FLAG | — |
| MAIN HEATING CATEGORY | boiler with radiators or underfloor heating |
| MAIN FUEL | mains gas (not community) |
| MAIN HEATING CONTROLS | 2106 |
| MECHANICAL VENTILATION | natural |
| ENERGY TARIFF | Single |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| NUMBER OPEN FIREPLACES | 0 |
| PHOTO SUPPLY | Array: Roof Area: 0%; Connection: not applicable (FGHRS or no PV); | |
| SOLAR WATER HEATING FLAG | N |
| TENURE | owner-occupied |
| TRANSACTION TYPE | marketed sale |
| UNHEATED CORRIDOR LENGTH | — |
| CONSTITUENCY | 00QQMD |
| CONSTITUENCY LABEL | Carse, Kinnaird and Tryst |
| WIND TURBINE COUNT | 0 |
| BUILT FORM | Mid-Terrace |
| PROPERTY TYPE | House |
| DATA ZONE 2011 | S01009090 (Larbert - North Broomage and Inches - 03) |
| CREATED AT | 04/07/2016 14:39:12 |
| REPORT REFERENCE NUMBER | 0000-2019-0829-7125-1663 |
| Source file | Q3 2016.csv |
| Address display | 41 MCCORMACK PLACE , LARBERT |
| Nation | scotland |