Energy Performance Certificate

25, Bowater Close, Calmore, SO40 2UU

EPC Report

Energy rating

Current: 70 C | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 71 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 85 Potential: 85
Field Value
LMK KEY 9972-2867-6021-9727-4291
ADDRESS1 25, Bowater Close
ADDRESS2 Calmore
ADDRESS3
POSTCODE SO40 2UU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2013-12-23
LOCAL AUTHORITY E07000091
CONSTITUENCY E14001373
COUNTY
LODGEMENT DATE 2013-12-23
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 152
ENERGY CONSUMPTION POTENTIAL 68
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 549
HEATING COST POTENTIAL 489
HOT WATER COST CURRENT 82
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 100
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 55
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 55% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 25, Bowater Close, Calmore
LOCAL AUTHORITY LABEL New Forest
CONSTITUENCY LABEL New Forest East
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2013-12-23 16:52:34
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100060501228
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000008
Address display
Nation ew