Energy Performance Certificate

182, Pollards Oak Road, RH8 0JP

EPC Report

Energy rating

Current: 46 E | Potential: 53 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 53 E Potential: 53 E

Environmental impact (CO₂)

Current: 36 | Potential: 41
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 41 Potential: 41
Field Value
LMK KEY 9969-2883-7529-9101-4341
ADDRESS1 182, Pollards Oak Road
ADDRESS2
ADDRESS3
POSTCODE RH8 0JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 53
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2019-12-07
LOCAL AUTHORITY E07000215
CONSTITUENCY E14001215
COUNTY
LODGEMENT DATE 2019-12-07
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 41
ENERGY CONSUMPTION CURRENT 829
ENERGY CONSUMPTION POTENTIAL 750
CO2 EMISSIONS CURRENT 3.7
CO2 EMISS CURR PER FLOOR AREA 140
CO2 EMISSIONS POTENTIAL 3.4
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 27
HEATING COST CURRENT 503
HEATING COST POTENTIAL 515
HOT WATER COST CURRENT 345
HOT WATER COST POTENTIAL 242
TOTAL FLOOR AREA 27
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 20
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 20% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 182, Pollards Oak Road
LOCAL AUTHORITY LABEL Tandridge
CONSTITUENCY LABEL East Surrey
POSTTOWN OXTED
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2019-12-07 17:55:42
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5