Energy Performance Certificate

12, Connaught Terrace, BN3 3YW

EPC Report

Energy rating

Current: 6 G | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 6 G Current: 6 G 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 25 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 Current: 25 80 Potential: 80
Field Value
LMK KEY 9967-2801-7804-9708-6415
ADDRESS1 12, Connaught Terrace
ADDRESS2
ADDRESS3
POSTCODE BN3 3YW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 6
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-10-09
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001296
COUNTY
LODGEMENT DATE 2018-10-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 25
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 555
ENERGY CONSUMPTION POTENTIAL 101
CO2 EMISSIONS CURRENT 9.7
CO2 EMISS CURR PER FLOOR AREA 94
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 82
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 2850
HEATING COST POTENTIAL 520
HOT WATER COST CURRENT 473
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 104
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.64
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Connaught Terrace
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Hove and Portslade
POSTTOWN HOVE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-10-09 12:08:30
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 22025232
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew