Energy Performance Certificate

22, Newtown Road, Haddenham, CB6 3TF

EPC Report

Energy rating

Current: 53 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 30 | Potential: 56
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 56 Potential: 56
Field Value
LMK KEY 9958-3010-7243-3975-6954
ADDRESS1 22, Newtown Road
ADDRESS2 Haddenham
ADDRESS3
POSTCODE CB6 3TF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-07-15
LOCAL AUTHORITY E07000009
CONSTITUENCY E14001224
COUNTY
LODGEMENT DATE 2015-07-15
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 56
ENERGY CONSUMPTION CURRENT 532
ENERGY CONSUMPTION POTENTIAL 273
CO2 EMISSIONS CURRENT 7.0
CO2 EMISS CURR PER FLOOR AREA 93
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 102
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 780
HEATING COST POTENTIAL 521
HOT WATER COST CURRENT 142
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 75
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Newtown Road, Haddenham
LOCAL AUTHORITY LABEL East Cambridgeshire
CONSTITUENCY LABEL Ely and East Cambridgeshire
POSTTOWN ELY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-07-15 21:16:12
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100090051421
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew