Energy Performance Certificate

9, Chelsea Close, Hampton Hill, TW12 1RS

EPC Report

Energy rating

Current: 43 E | Potential: 64 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 64 D Potential: 64 D

Environmental impact (CO₂)

Current: 39 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 64 Potential: 64
Field Value
LMK KEY 9918-2033-6217-5265-7960
ADDRESS1 9, Chelsea Close
ADDRESS2 Hampton Hill
ADDRESS3
POSTCODE TW12 1RS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 64
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2015-03-19
LOCAL AUTHORITY E09000027
CONSTITUENCY E14001556
COUNTY
LODGEMENT DATE 2015-03-24
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 594
ENERGY CONSUMPTION POTENTIAL 327
CO2 EMISSIONS CURRENT 3.5
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 30
LIGHTING COST POTENTIAL 30
HEATING COST CURRENT 593
HEATING COST POTENTIAL 370
HOT WATER COST CURRENT 173
HOT WATER COST POTENTIAL 94
TOTAL FLOOR AREA 33
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 3.5
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Chelsea Close, Hampton Hill
LOCAL AUTHORITY LABEL Richmond upon Thames
CONSTITUENCY LABEL Twickenham
POSTTOWN HAMPTON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-03-24 08:41:03
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100022277795
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display