Energy Performance Certificate

10 RYTHERGATE, CAWOOD, SELBY, YO8 3TP

EPC Report

Energy rating

Current: 27 F | Potential: 38 F
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 38 F Potential: 38 F

Environmental impact (CO₂)

Current: 37 | Potential: 45
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 45 Potential: 45
Field Value
LMK KEY 9910-1005-1209-2859-0200
ADDRESS1 10 RYTHERGATE
ADDRESS2 CAWOOD
ADDRESS3 SELBY
POSTCODE YO8 3TP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING F
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 38
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2021-01-19
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001464
COUNTY
LODGEMENT DATE 2021-02-04
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 45
ENERGY CONSUMPTION CURRENT 379
ENERGY CONSUMPTION POTENTIAL 312
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 9.5
LIGHTING COST CURRENT 123
LIGHTING COST POTENTIAL 123
HEATING COST CURRENT 3656
HEATING COST POTENTIAL 3399
HOT WATER COST CURRENT 438
HOT WATER COST POTENTIAL 282
TOTAL FLOOR AREA 181
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 RYTHERGATE, CAWOOD, SELBY
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Selby
POSTTOWN SELBY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-02-04 09:25:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 16
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100050521008
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000003
Address display
Nation ew