Energy Performance Certificate
21 The Wills Building, Wills Oval, NE7 7RW
Energy rating
Current: 79 C | Potential: 79 C
Environmental impact (CO₂)
Current: 79
| Potential: 79
| Field | Value |
|---|---|
| LMK KEY | 9900-0804-0522-0474-3453 |
| ADDRESS1 | 21 The Wills Building |
| ADDRESS2 | Wills Oval |
| ADDRESS3 | — |
| POSTCODE | NE7 7RW |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | C |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 79 |
| POTENTIAL ENERGY EFFICIENCY | 79 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2025-04-30 |
| LOCAL AUTHORITY | E08000021 |
| CONSTITUENCY | E14001378 |
| COUNTY | — |
| LODGEMENT DATE | 2025-04-30 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 79 |
| ENVIRONMENT IMPACT POTENTIAL | 79 |
| ENERGY CONSUMPTION CURRENT | 146 |
| ENERGY CONSUMPTION POTENTIAL | 146 |
| CO2 EMISSIONS CURRENT | 1.8 |
| CO2 EMISS CURR PER FLOOR AREA | 26 |
| CO2 EMISSIONS POTENTIAL | 1.8 |
| LIGHTING COST CURRENT | 101 |
| LIGHTING COST POTENTIAL | 101 |
| HEATING COST CURRENT | 339 |
| HEATING COST POTENTIAL | 339 |
| HOT WATER COST CURRENT | 169 |
| HOT WATER COST POTENTIAL | 169 |
| TOTAL FLOOR AREA | 69 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | 1 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Charging system linked to use of community heating, programmer and room thermostat |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, limited insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Solid brick, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (another dwelling above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Charging system linked to use of community heating, programmer and room thermostat |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Low energy lighting in all fixed outlets |
| LIGHTING ENERGY EFF | Very Good |
| LIGHTING ENV EFF | Very Good |
| MAIN FUEL | mains gas (community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | unheated corridor |
| UNHEATED CORRIDOR LENGTH | 6.1 |
| FLOOR HEIGHT | 3.3 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 21 The Wills Building, Wills Oval |
| LOCAL AUTHORITY LABEL | Newcastle upon Tyne |
| CONSTITUENCY LABEL | Newcastle upon Tyne East and Wallsend |
| POSTTOWN | NEWCASTLE UPON TYNE |
| CONSTRUCTION AGE BAND | England and Wales: 1996-2002 |
| LODGEMENT DATETIME | 2025-04-30 13:34:11 |
| TENURE | owner-occupied |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 11 |
| UPRN | 4510133544 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2025.csv |
| COUNTRY | England |
| REGION | E12000001 |
| Address display | — |
| Nation | ew |