Energy Performance Certificate

2, Brooklands Close, HU17 9PS

EPC Report

Energy rating

Current: 33 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 30 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 82 Potential: 82
Field Value
LMK KEY 9898-9089-7274-4636-8904
ADDRESS1 2, Brooklands Close
ADDRESS2
ADDRESS3
POSTCODE HU17 9PS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2016-04-11
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001087
COUNTY
LODGEMENT DATE 2016-05-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 549
ENERGY CONSUMPTION POTENTIAL 110
CO2 EMISSIONS CURRENT 7.7
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 53
HEATING COST CURRENT 1238
HEATING COST POTENTIAL 499
HOT WATER COST CURRENT 410
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Brooklands Close
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Beverley and Holderness
POSTTOWN BEVERLEY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-05-01 08:28:36
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100050001017
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew