Energy Performance Certificate

5 East View, Hellifield, BD23 4EU

EPC Report

Energy rating

Current: 30 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 12 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 Current: 12 80 Potential: 80
Field Value
LMK KEY 9897-0075-0203-8982-5200
ADDRESS1 5 East View
ADDRESS2 Hellifield
ADDRESS3
POSTCODE BD23 4EU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-07-11
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001475
COUNTY
LODGEMENT DATE 2022-07-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 12
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 980
ENERGY CONSUMPTION POTENTIAL 150
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 166
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 93
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 2015
HEATING COST POTENTIAL 496
HOT WATER COST CURRENT 280
HOT WATER COST POTENTIAL 66
TOTAL FLOOR AREA 75
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.89
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5 East View, Hellifield
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Skipton and Ripon
POSTTOWN SKIPTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-07-11 15:24:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 10007558807
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000003
Address display
Nation ew