Energy Performance Certificate
Room 2, 23 Marshworth, Tinkers Bridge, MK6 3DA
Energy rating
Current: 59 D | Potential: 59 D
Environmental impact (CO₂)
Current: 63
| Potential: 63
| Field | Value |
|---|---|
| LMK KEY | 9889-3011-1306-3866-7204 |
| ADDRESS1 | Room 2 |
| ADDRESS2 | 23 Marshworth |
| ADDRESS3 | Tinkers Bridge |
| POSTCODE | MK6 3DA |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | D |
| CURRENT ENERGY EFFICIENCY | 59 |
| POTENTIAL ENERGY EFFICIENCY | 59 |
| PROPERTY TYPE | Flat |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2026-06-18 |
| LOCAL AUTHORITY | E06000042 |
| CONSTITUENCY | E14001369 |
| COUNTY | — |
| LODGEMENT DATE | 2026-06-18 |
| TRANSACTION TYPE | None of the above |
| ENVIRONMENT IMPACT CURRENT | 63 |
| ENVIRONMENT IMPACT POTENTIAL | 63 |
| ENERGY CONSUMPTION CURRENT | 744 |
| ENERGY CONSUMPTION POTENTIAL | 744 |
| CO2 EMISSIONS CURRENT | 1.5 |
| CO2 EMISS CURR PER FLOOR AREA | 136.8 |
| CO2 EMISSIONS POTENTIAL | 1.5 |
| LIGHTING COST CURRENT | 15 |
| LIGHTING COST POTENTIAL | 15 |
| HEATING COST CURRENT | 238 |
| HEATING COST POTENTIAL | 238 |
| HOT WATER COST CURRENT | 328 |
| HOT WATER COST POTENTIAL | 328 |
| TOTAL FLOOR AREA | 11 |
| ENERGY TARIFF | standard tariff |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | 1 |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 1 |
| MAIN HEATING CONTROLS | Flat rate charging, programmer and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | — |
| NUMBER HABITABLE ROOMS | — |
| NUMBER HEATED ROOMS | — |
| LOW ENERGY LIGHTING | 100 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Community scheme |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Average thermal transmittance 0.18 W/m²K |
| FLOOR ENERGY EFF | Very Good |
| FLOOR ENV EFF | Very Good |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Average thermal transmittance 0.25 W/m²K |
| WALLS ENERGY EFF | Very Good |
| WALLS ENV EFF | Very Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | (other premises above) |
| ROOF ENERGY EFF | N/A |
| ROOF ENV EFF | N/A |
| MAINHEAT DESCRIPTION | Community scheme |
| MAINHEAT ENERGY EFF | Poor |
| MAINHEAT ENV EFF | Poor |
| MAINHEATCONT DESCRIPTION | Flat rate charging, programmer and TRVs |
| MAINHEATC ENERGY EFF | Average |
| MAINHEATC ENV EFF | Average |
| LIGHTING DESCRIPTION | Good lighting efficiency |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| MAIN FUEL | — |
| WIND TURBINE COUNT | — |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | — |
| MECHANICAL VENTILATION | — |
| ADDRESS | Room 2, 23 Marshworth, Tinkers Bridge |
| LOCAL AUTHORITY LABEL | Milton Keynes |
| CONSTITUENCY LABEL | Milton Keynes Central |
| POSTTOWN | MILTON KEYNES |
| CONSTRUCTION AGE BAND | 2026 |
| LODGEMENT DATETIME | 2026-06-18 11:24:51 |
| TENURE | unknown |
| FIXED LIGHTING OUTLETS COUNT | 3 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| UPRN | — |
| UPRN SOURCE | — |
| REPORT TYPE | 3 |
| Source file | certificates-2026.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |