Energy Performance Certificate

30 Northgate Street, SY23 2JS

EPC Report

Energy rating

Current: 51 E | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 42 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 72 Potential: 72
Field Value
LMK KEY 9879-3945-4202-3484-1200
ADDRESS1 30 Northgate Street
ADDRESS2
ADDRESS3
POSTCODE SY23 2JS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2024-12-13
LOCAL AUTHORITY W06000008
CONSTITUENCY W07000093
COUNTY
LODGEMENT DATE 2024-12-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 335
ENERGY CONSUMPTION POTENTIAL 148
CO2 EMISSIONS CURRENT 8.6
CO2 EMISS CURR PER FLOOR AREA 59
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 253
LIGHTING COST POTENTIAL 129
HEATING COST CURRENT 2100
HEATING COST POTENTIAL 1245
HOT WATER COST CURRENT 267
HOT WATER COST POTENTIAL 135
TOTAL FLOOR AREA 146
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 30 Northgate Street
LOCAL AUTHORITY LABEL Ceredigion
CONSTITUENCY LABEL Ceredigion Preseli
POSTTOWN ABERYSTWYTH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2024-12-18 13:00:03
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 49021521
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew