Energy Performance Certificate

Crest House, South Newbald Road, North Newbald, YO43 4SX

EPC Report

Energy rating

Current: 62 D | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 65 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 90 Potential: 90
Field Value
LMK KEY 9878-2075-7241-1553-8970
ADDRESS1 Crest House
ADDRESS2 South Newbald Road
ADDRESS3 North Newbald
POSTCODE YO43 4SX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2017-09-13
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001087
COUNTY
LODGEMENT DATE 2017-09-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 185
ENERGY CONSUMPTION POTENTIAL 56
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 110
LIGHTING COST POTENTIAL 110
HEATING COST CURRENT 1917
HEATING COST POTENTIAL 1282
HOT WATER COST CURRENT 248
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 241
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 97
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 97% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.72
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Crest House, South Newbald Road, North Newbald
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Beverley and Holderness
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-09-13 21:39:20
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 34
UPRN 100050115808
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew