Energy Performance Certificate

149a Breach Road, DE75 7HQ

EPC Report

Energy rating

Current: 67 D | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 62 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 69 Potential: 69
Field Value
LMK KEY 9869-3944-9209-9084-0204
ADDRESS1 149a Breach Road
ADDRESS2
ADDRESS3
POSTCODE DE75 7HQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2024-11-16
LOCAL AUTHORITY E07000032
CONSTITUENCY E14001066
COUNTY
LODGEMENT DATE 2024-11-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 187
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 33
CO2 EMISSIONS POTENTIAL 6.1
LIGHTING COST CURRENT 159
LIGHTING COST POTENTIAL 159
HEATING COST CURRENT 2223
HEATING COST POTENTIAL 2080
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 228
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 149a Breach Road
LOCAL AUTHORITY LABEL Amber Valley
CONSTITUENCY LABEL Amber Valley
POSTTOWN HEANOR
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2024-11-17 17:36:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 36
LOW ENERGY FIXED LIGHT COUNT 36
UPRN 100030026140
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000004
Address display
Nation ew