Energy Performance Certificate

28, Seed Close Lane, Laceby, DN37 7AE

EPC Report

Energy rating

Current: 45 E | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 E Current: 45 E 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 37 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 63 Potential: 63
Field Value
LMK KEY 9868-2059-7219-4126-4934
ADDRESS1 28, Seed Close Lane
ADDRESS2 Laceby
ADDRESS3
POSTCODE DN37 7AE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 45
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-01-16
LOCAL AUTHORITY E06000012
CONSTITUENCY E14001128
COUNTY
LODGEMENT DATE 2016-02-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 410
ENERGY CONSUMPTION POTENTIAL 212
CO2 EMISSIONS CURRENT 8.1
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 4.2
LIGHTING COST CURRENT 115
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1350
HEATING COST POTENTIAL 1006
HOT WATER COST CURRENT 288
HOT WATER COST POTENTIAL 89
TOTAL FLOOR AREA 111
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 76
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 28, Seed Close Lane, Laceby
LOCAL AUTHORITY LABEL North East Lincolnshire
CONSTITUENCY LABEL Brigg and Immingham
POSTTOWN GRIMSBY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-02-12 09:49:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 11049513
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew