Energy Performance Certificate

The Heights, Hillhead, EX24 6HH

EPC Report

Energy rating

Current: 73 C | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 75 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 88 Potential: 88
Field Value
LMK KEY 9868-0012-7293-3211-3904
ADDRESS1 The Heights
ADDRESS2 Hillhead
ADDRESS3
POSTCODE EX24 6HH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-07-16
LOCAL AUTHORITY E07000040
CONSTITUENCY E14001291
COUNTY
LODGEMENT DATE 2019-07-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 145
ENERGY CONSUMPTION POTENTIAL 69
CO2 EMISSIONS CURRENT 3.5
CO2 EMISS CURR PER FLOOR AREA 22
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 163
LIGHTING COST POTENTIAL 94
HEATING COST CURRENT 1111
HEATING COST POTENTIAL 1129
HOT WATER COST CURRENT 125
HOT WATER COST POTENTIAL 125
TOTAL FLOOR AREA 157
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 27
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Ground source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 27% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 20
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS The Heights, Hillhead
LOCAL AUTHORITY LABEL East Devon
CONSTITUENCY LABEL Honiton and Sidmouth
POSTTOWN COLYTON
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2019-07-17 17:27:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 33
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100040160054
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000009
Address display
Nation ew