Energy Performance Certificate

42a, Abingdon Grove, Walton, L4 9XB

EPC Report

Energy rating

Current: 74 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 75 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 Current: 75 80 Potential: 80
Field Value
LMK KEY 9848-7096-6248-7772-1980
ADDRESS1 42a, Abingdon Grove
ADDRESS2 Walton
ADDRESS3
POSTCODE L4 9XB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2012-08-14
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001339
COUNTY
LODGEMENT DATE 2012-08-15
TRANSACTION TYPE rental (private)
ENVIRONMENT IMPACT CURRENT 75
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 155
ENERGY CONSUMPTION POTENTIAL 122
CO2 EMISSIONS CURRENT 2.2
CO2 EMISS CURR PER FLOOR AREA 30
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 45
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 369
HEATING COST POTENTIAL 308
HOT WATER COST CURRENT 104
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH 6.5
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 42a, Abingdon Grove, Walton
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Walton
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2012-08-15 11:26:03
TENURE
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 38175426
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000002
Address display
Nation ew