Energy Performance Certificate

27, Main Street, Goadby Marwood, LE14 4LN

EPC Report

Energy rating

Current: 11 G | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 G Current: 11 G 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 12 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 Current: 12 73 Potential: 73
Field Value
LMK KEY 9847-2889-7694-9106-3941
ADDRESS1 27, Main Street
ADDRESS2 Goadby Marwood
ADDRESS3
POSTCODE LE14 4LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 11
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-11-01
LOCAL AUTHORITY E07000133
CONSTITUENCY E14001357
COUNTY
LODGEMENT DATE 2016-11-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 12
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 505
ENERGY CONSUMPTION POTENTIAL 97
CO2 EMISSIONS CURRENT 17
CO2 EMISS CURR PER FLOOR AREA 132
CO2 EMISSIONS POTENTIAL 3.6
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 74
HEATING COST CURRENT 2197
HEATING COST POTENTIAL 609
HOT WATER COST CURRENT 403
HOT WATER COST POTENTIAL 84
TOTAL FLOOR AREA 129
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 42
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 42% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27, Main Street, Goadby Marwood
LOCAL AUTHORITY LABEL Melton
CONSTITUENCY LABEL Melton and Syston
POSTTOWN MELTON MOWBRAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-11-01 22:59:21
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100030533807
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew