Energy Performance Certificate

53 Beckett Road, DN2 4AD

EPC Report

Energy rating

Current: 78 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 54 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 57 Potential: 57
Field Value
LMK KEY 9837-8922-5309-0179-2202
ADDRESS1 53 Beckett Road
ADDRESS2
ADDRESS3
POSTCODE DN2 4AD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-12-01
LOCAL AUTHORITY E08000017
CONSTITUENCY E14001198
COUNTY
LODGEMENT DATE 2024-01-15
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 255
ENERGY CONSUMPTION POTENTIAL 237
CO2 EMISSIONS CURRENT 6.2
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 5.7
LIGHTING COST CURRENT 158
LIGHTING COST POTENTIAL 186
HEATING COST CURRENT 2990
HEATING COST POTENTIAL 2053
HOT WATER COST CURRENT 535
HOT WATER COST POTENTIAL 237
TOTAL FLOOR AREA 143
ENERGY TARIFF dual (24 hour)
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.1
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 53 Beckett Road
LOCAL AUTHORITY LABEL Doncaster
CONSTITUENCY LABEL Doncaster Central
POSTTOWN DONCASTER
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2024-01-15 17:00:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 23
LOW ENERGY FIXED LIGHT COUNT 23
UPRN 100050697588
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2024.csv
COUNTRY England
REGION E12000003
Address display
Nation ew