Energy Performance Certificate

9, East Road, E15 3QS

EPC Report

Energy rating

Current: 1 G | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 1 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 72 Potential: 72
Field Value
LMK KEY 9831-2897-7708-9795-8331
ADDRESS1 9, East Road
ADDRESS2
ADDRESS3
POSTCODE E15 3QS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-10-13
LOCAL AUTHORITY E09000025
CONSTITUENCY E14001576
COUNTY
LODGEMENT DATE 2015-10-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 1000
ENERGY CONSUMPTION POTENTIAL 124
CO2 EMISSIONS CURRENT 20
CO2 EMISS CURR PER FLOOR AREA 176
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 132
LIGHTING COST POTENTIAL 132
HEATING COST CURRENT 3650
HEATING COST POTENTIAL 607
HOT WATER COST CURRENT 340
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 111
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 5
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 270 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.82
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, East Road
LOCAL AUTHORITY LABEL Newham
CONSTITUENCY LABEL West Ham and Beckton
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2015-10-13 14:32:14
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 49
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 46022986
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew