Energy Performance Certificate

First Floor Studio Flat, 48 Cricklewood Broadway, NW2 3ET

EPC Report

Energy rating

Current: 50 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 E Current: 50 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 55 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 68 Potential: 68
Field Value
LMK KEY 9828-7007-7241-5033-9970
ADDRESS1 First Floor Studio Flat
ADDRESS2 48 Cricklewood Broadway
ADDRESS3
POSTCODE NW2 3ET
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 50
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2017-09-12
LOCAL AUTHORITY E09000007
CONSTITUENCY E14001265
COUNTY
LODGEMENT DATE 2017-09-14
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 527
ENERGY CONSUMPTION POTENTIAL 381
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 89
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 34
LIGHTING COST POTENTIAL 22
HEATING COST CURRENT 453
HEATING COST POTENTIAL 162
HOT WATER COST CURRENT 131
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 23
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.38
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS First Floor Studio Flat, 48 Cricklewood Broadway
LOCAL AUTHORITY LABEL Camden
CONSTITUENCY LABEL Hampstead and Highgate
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-09-14 12:57:19
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 3
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 5075634
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000007
Address display
Nation ew