Energy Performance Certificate

HIGH GROVE, GREENWAY LANE, CHARLTON KINGS, GL52 6LA

EPC Report

Energy rating

Current: 54 E | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 43 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 74 Potential: 74
Field Value
LMK KEY 9816-3179-3102-0204-2006
ADDRESS1 HIGH GROVE
ADDRESS2 GREENWAY LANE
ADDRESS3 CHARLTON KINGS
POSTCODE GL52 6LA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2021-04-08
LOCAL AUTHORITY E07000078
CONSTITUENCY E14001161
COUNTY
LODGEMENT DATE 2021-04-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 297
ENERGY CONSUMPTION POTENTIAL 123
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 113
HEATING COST CURRENT 1577
HEATING COST POTENTIAL 785
HOT WATER COST CURRENT 129
HOT WATER COST POTENTIAL 130
TOTAL FLOOR AREA 173
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 93
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 400+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 93% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.65
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS HIGH GROVE, GREENWAY LANE, CHARLTON KINGS
LOCAL AUTHORITY LABEL Cheltenham
CONSTITUENCY LABEL Cheltenham
POSTTOWN CHELTENHAM
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2021-04-09 16:59:21
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 28
LOW ENERGY FIXED LIGHT COUNT 26
UPRN 100121233906
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000009
Address display
Nation ew