Energy Performance Certificate

93 GLOSTER ROAD, OLD WOKING, WOKING, GU22 9EU

EPC Report

Energy rating

Current: 66 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 62 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 Current: 62 86 Potential: 86
Field Value
LMK KEY 9809-3903-7202-3650-2200
ADDRESS1 93 GLOSTER ROAD
ADDRESS2 OLD WOKING
ADDRESS3 WOKING
POSTCODE GU22 9EU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-12-10
LOCAL AUTHORITY E07000217
CONSTITUENCY E14001592
COUNTY
LODGEMENT DATE 2021-01-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 62
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 252
ENERGY CONSUMPTION POTENTIAL 78
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 76
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 358
HEATING COST POTENTIAL 353
HOT WATER COST CURRENT 250
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 68
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, with external insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 93 GLOSTER ROAD, OLD WOKING, WOKING
LOCAL AUTHORITY LABEL Woking
CONSTITUENCY LABEL Woking
POSTTOWN WOKING
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2021-01-21 20:09:41
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100061644863
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000008
Address display
Nation ew