Energy Performance Certificate

106, Semley Road, SW16 4PJ

EPC Report

Energy rating

Current: 25 F | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 25 F Current: 25 F 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 36 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 86 Potential: 86
Field Value
LMK KEY 9808-0971-7210-2884-3950
ADDRESS1 106, Semley Road
ADDRESS2
ADDRESS3
POSTCODE SW16 4PJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 25
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-10-10
LOCAL AUTHORITY E09000008
CONSTITUENCY E14001527
COUNTY
LODGEMENT DATE 2014-10-13
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 412
ENERGY CONSUMPTION POTENTIAL 67
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 74
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 1585
HEATING COST POTENTIAL 473
HOT WATER COST CURRENT 379
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 97
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 75
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 44
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 44% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.62
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 106, Semley Road
LOCAL AUTHORITY LABEL Croydon
CONSTITUENCY LABEL Streatham and Croydon North
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-10-13 18:21:58
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100020657326
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000007
Address display
Nation ew