Energy Performance Certificate

3, Broad Street, BN2 1TJ

EPC Report

Energy rating

Current: 51 E | Potential: 75 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 75 C Potential: 75 C

Environmental impact (CO₂)

Current: 44 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 Current: 44 70 Potential: 70
Field Value
LMK KEY 9807-2834-7429-9702-8165
ADDRESS1 3, Broad Street
ADDRESS2
ADDRESS3
POSTCODE BN2 1TJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 75
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2012-12-04
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001129
COUNTY
LODGEMENT DATE 2012-12-07
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 44
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 253
ENERGY CONSUMPTION POTENTIAL 122
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 5.7
LIGHTING COST CURRENT 140
LIGHTING COST POTENTIAL 95
HEATING COST CURRENT 1876
HEATING COST POTENTIAL 1099
HOT WATER COST CURRENT 186
HOT WATER COST POTENTIAL 118
TOTAL FLOOR AREA 240
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 5
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 38
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.13
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Broad Street
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Kemptown and Peacehaven
POSTTOWN BRIGHTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2012-12-07 14:25:14
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 22235080
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000008
Address display
Nation ew