Energy Performance Certificate

22, Heol Tredeg, Upper Cwmtwrch, SA9 2XD

EPC Report

Energy rating

Current: 23 F | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 F Current: 23 F 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 20 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 80 Potential: 80
Field Value
LMK KEY 9807-2834-7125-9602-5745
ADDRESS1 22, Heol Tredeg
ADDRESS2 Upper Cwmtwrch
ADDRESS3
POSTCODE SA9 2XD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 23
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-12-04
LOCAL AUTHORITY W06000023
CONSTITUENCY W07000085
COUNTY
LODGEMENT DATE 2012-12-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 471
ENERGY CONSUMPTION POTENTIAL 58
CO2 EMISSIONS CURRENT 9.4
CO2 EMISS CURR PER FLOOR AREA 113
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 1597
HEATING COST POTENTIAL 424
HOT WATER COST CURRENT 146
HOT WATER COST POTENTIAL 89
TOTAL FLOOR AREA 83
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 60
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.54
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Heol Tredeg, Upper Cwmtwrch
LOCAL AUTHORITY LABEL Powys
CONSTITUENCY LABEL Brecon, Radnor and Cwm Tawe
POSTTOWN SWANSEA
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-12-05 20:14:25
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 10011794367
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew