Energy Performance Certificate

3 Valley Place, Lower Eashing, GU7 2QG

EPC Report

Energy rating

Current: 52 E | Potential: 96 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 96 A Potential: 96 A

Environmental impact (CO₂)

Current: 33 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 81 Potential: 81
Field Value
LMK KEY 9798-0099-7277-2104-7980
ADDRESS1 3 Valley Place
ADDRESS2 Lower Eashing
ADDRESS3
POSTCODE GU7 2QG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 96
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-03-11
LOCAL AUTHORITY E07000209
CONSTITUENCY E14001249
COUNTY
LODGEMENT DATE 2014-03-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 585
ENERGY CONSUMPTION POTENTIAL 135
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 105
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 64
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 526
HEATING COST POTENTIAL 215
HOT WATER COST CURRENT 197
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 47
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 10
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 10% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3 Valley Place, Lower Eashing
LOCAL AUTHORITY LABEL Guildford
CONSTITUENCY LABEL Godalming and Ash
POSTTOWN GODALMING
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-03-12 13:51:16
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10007062660
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000008
Address display
Nation ew