Energy Performance Certificate

36, Morgans Way, Hevingham, NR10 5PD

EPC Report

Energy rating

Current: 54 E | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 49 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 80 Potential: 80
Field Value
LMK KEY 9798-0063-6296-9264-0930
ADDRESS1 36, Morgans Way
ADDRESS2 Hevingham
ADDRESS3
POSTCODE NR10 5PD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2014-06-11
LOCAL AUTHORITY E07000144
CONSTITUENCY E14001136
COUNTY
LODGEMENT DATE 2014-06-26
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 297
ENERGY CONSUMPTION POTENTIAL 107
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 893
HEATING COST POTENTIAL 544
HOT WATER COST CURRENT 133
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300+ mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 36, Morgans Way, Hevingham
LOCAL AUTHORITY LABEL Broadland
CONSTITUENCY LABEL Broadland and Fakenham
POSTTOWN NORWICH
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2014-06-26 14:13:15
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100090815688
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000006
Address display
Nation ew