Energy Performance Certificate

2, Torchil Close, Anlaby, HU10 7HR

EPC Report

Energy rating

Current: 63 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 57 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 76 Potential: 76
Field Value
LMK KEY 9788-2016-7297-6790-7254
ADDRESS1 2, Torchil Close
ADDRESS2 Anlaby
ADDRESS3
POSTCODE HU10 7HR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2020-03-18
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001315
COUNTY
LODGEMENT DATE 2020-03-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 286
ENERGY CONSUMPTION POTENTIAL 150
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 674
HEATING COST POTENTIAL 549
HOT WATER COST CURRENT 101
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.59
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Torchil Close, Anlaby
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Kingston upon Hull West and Haltemprice
POSTTOWN HULL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-03-18 15:32:43
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 100052013499
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000003
Address display