Energy Performance Certificate

Flat 11, 85, Fairfield Road, E3 2QF

EPC Report

Energy rating

Current: 62 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 65 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 65 Potential: 65
Field Value
LMK KEY 9778-7045-7218-3540-9230
ADDRESS1 Flat 11
ADDRESS2 85, Fairfield Road
ADDRESS3
POSTCODE E3 2QF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM End-Terrace
INSPECTION DATE 2020-08-13
LOCAL AUTHORITY E09000030
CONSTITUENCY E14001525
COUNTY
LODGEMENT DATE 2020-08-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 268
ENERGY CONSUMPTION POTENTIAL 271
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 54
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 399
HEATING COST POTENTIAL 181
HOT WATER COST CURRENT 255
HOT WATER COST POTENTIAL 155
TOTAL FLOOR AREA 43
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 11, 85, Fairfield Road
LOCAL AUTHORITY LABEL Tower Hamlets
CONSTITUENCY LABEL Stratford and Bow
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2020-08-17 22:03:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 6031038
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000007
Address display
Nation ew