Energy Performance Certificate

Dolphins Bend, Epney, Saul, GL2 7LN

EPC Report

Energy rating

Current: 36 F | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 F Current: 36 F 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 31 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 61 Potential: 61
Field Value
LMK KEY 9778-4058-7255-0087-5964
ADDRESS1 Dolphins Bend
ADDRESS2 Epney
ADDRESS3 Saul
POSTCODE GL2 7LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 36
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-05-13
LOCAL AUTHORITY E07000082
CONSTITUENCY E14001386
COUNTY
LODGEMENT DATE 2013-05-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 396
ENERGY CONSUMPTION POTENTIAL 173
CO2 EMISSIONS CURRENT 8.4
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1301
HEATING COST POTENTIAL 815
HOT WATER COST CURRENT 329
HOT WATER COST POTENTIAL 163
TOTAL FLOOR AREA 109
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Dolphins Bend, Epney, Saul
LOCAL AUTHORITY LABEL Stroud
CONSTITUENCY LABEL North Cotswolds
POSTTOWN GLOUCESTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-05-17 16:04:36
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 200003104301
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew