Energy Performance Certificate

62 JASPER HOUSE, 9 MERRIVALE MEWS, CENTRAL MILTON KEYNES, MK9 2FN

EPC Report

Energy rating

Current: 78 C | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 80 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 Current: 80 80 Potential: 80
Field Value
LMK KEY 9767-0902-1202-2810-5200
ADDRESS1 62 JASPER HOUSE
ADDRESS2 9 MERRIVALE MEWS
ADDRESS3 CENTRAL MILTON KEYNES
POSTCODE MK9 2FN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE Flat
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2020-12-16
LOCAL AUTHORITY E06000042
CONSTITUENCY E14001369
COUNTY
LODGEMENT DATE 2020-12-16
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 80
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 163
ENERGY CONSUMPTION POTENTIAL 159
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 29
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 204
HEATING COST POTENTIAL 206
HOT WATER COST CURRENT 99
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 48
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Charging system linked to use of community heating, programmer and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Charging system linked to use of community heating, programmer and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR heated corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 62 JASPER HOUSE, 9 MERRIVALE MEWS, CENTRAL MILTON KEYNES
LOCAL AUTHORITY LABEL Milton Keynes
CONSTITUENCY LABEL Milton Keynes Central
POSTTOWN MILTON KEYNES
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2020-12-16 11:44:31
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 25121744
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew