Energy Performance Certificate

10 Bucklands, Bideford Bay Holiday Park, Bucks Cross, EX39 5DU

EPC Report

Energy rating

Current: 22 F | Potential: 119 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 F Current: 22 F 119 A Potential: 119 A

Environmental impact (CO₂)

Current: 33 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 88 Potential: 88
Field Value
LMK KEY 9748-2800-7898-9495-8781
ADDRESS1 10 Bucklands
ADDRESS2 Bideford Bay Holiday Park
ADDRESS3 Bucks Cross
POSTCODE EX39 5DU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 22
POTENTIAL ENERGY EFFICIENCY 119
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2015-11-10
LOCAL AUTHORITY E07000046
CONSTITUENCY E14001552
COUNTY
LODGEMENT DATE 2015-11-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 659
ENERGY CONSUMPTION POTENTIAL 11
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 111
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 49
LIGHTING COST POTENTIAL 30
HEATING COST CURRENT 886
HEATING COST POTENTIAL 374
HOT WATER COST CURRENT 253
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 37
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.22
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Bucklands, Bideford Bay Holiday Park, Bucks Cross
LOCAL AUTHORITY LABEL Torridge
CONSTITUENCY LABEL Torridge and Tavistock
POSTTOWN BIDEFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-11-10 17:09:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 10023350703
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew