Energy Performance Certificate

35, Milner ING, Wyke, BD12 8DR

EPC Report

Energy rating

Current: 60 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 54 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 74 Potential: 74
Field Value
LMK KEY 9747-2832-7020-9496-9291
ADDRESS1 35, Milner ING
ADDRESS2 Wyke
ADDRESS3
POSTCODE BD12 8DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-12-12
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001119
COUNTY
LODGEMENT DATE 2016-12-15
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 302
ENERGY CONSUMPTION POTENTIAL 171
CO2 EMISSIONS CURRENT 4.7
CO2 EMISS CURR PER FLOOR AREA 53
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 116
LIGHTING COST POTENTIAL 58
HEATING COST CURRENT 830
HEATING COST POTENTIAL 686
HOT WATER COST CURRENT 121
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 88
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.51
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35, Milner ING, Wyke
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Bradford South
POSTTOWN BRADFORD
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-12-15 14:09:34
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100051195124
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew