Energy Performance Certificate

Flat 3, 109 High Street, LL57 1NS

EPC Report

Energy rating

Current: 29 F | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 F Current: 29 F 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 17 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 17 Current: 17 65 Potential: 65
Field Value
LMK KEY 9746-2875-7800-9606-2331
ADDRESS1 Flat 3
ADDRESS2 109 High Street
ADDRESS3
POSTCODE LL57 1NS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 29
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-10-05
LOCAL AUTHORITY W06000002
CONSTITUENCY W07000083
COUNTY
LODGEMENT DATE 2016-10-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 17
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 1008
ENERGY CONSUMPTION POTENTIAL 311
CO2 EMISSIONS CURRENT 6.5
CO2 EMISS CURR PER FLOOR AREA 170
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 47
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 923
HEATING COST POTENTIAL 171
HOT WATER COST CURRENT 226
HOT WATER COST POTENTIAL 120
TOTAL FLOOR AREA 38
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.48
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 3, 109 High Street
LOCAL AUTHORITY LABEL Gwynedd
CONSTITUENCY LABEL Bangor Aberconwy
POSTTOWN BANGOR
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-10-06 15:23:19
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 200003194279
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew