Energy Performance Certificate

10 Threshers Court, Hollins Lane, Forton, PR3 0BS

EPC Report

Energy rating

Current: 62 D | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 43 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 Current: 43 70 Potential: 70
Field Value
LMK KEY 9741-3012-5209-0702-6204
ADDRESS1 10 Threshers Court
ADDRESS2 Hollins Lane
ADDRESS3 Forton
POSTCODE PR3 0BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-01-14
LOCAL AUTHORITY E07000128
CONSTITUENCY E14001318
COUNTY
LODGEMENT DATE 2022-01-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 43
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 456
ENERGY CONSUMPTION POTENTIAL 227
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 776
HEATING COST POTENTIAL 518
HOT WATER COST CURRENT 190
HOT WATER COST POTENTIAL 108
TOTAL FLOOR AREA 62
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), ceiling insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.24
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10 Threshers Court, Hollins Lane, Forton
LOCAL AUTHORITY LABEL Wyre
CONSTITUENCY LABEL Lancaster and Wyre
POSTTOWN PRESTON
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2022-01-14 22:07:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100012422411
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000002
Address display
Nation ew