Energy Performance Certificate

69 Holborn Avenue, NG2 4LY

EPC Report

Energy rating

Current: 66 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 61 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 80 Potential: 80
Field Value
LMK KEY 9739-1015-8238-2982-5200
ADDRESS1 69 Holborn Avenue
ADDRESS2
ADDRESS3
POSTCODE NG2 4LY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2022-08-17
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001410
COUNTY
LODGEMENT DATE 2022-08-18
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 248
ENERGY CONSUMPTION POTENTIAL 118
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 61
LIGHTING COST POTENTIAL 61
HEATING COST CURRENT 516
HEATING COST POTENTIAL 434
HOT WATER COST CURRENT 91
HOT WATER COST POTENTIAL 63
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 69 Holborn Avenue
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham East
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2022-08-18 09:19:41
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100031558289
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000004
Address display
Nation ew