Energy Performance Certificate

10, Fairfax Drive, S2 1SJ

EPC Report

Energy rating

Current: 76 C | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 C Current: 76 C 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 76 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 76 Current: 76 88 Potential: 88
Field Value
LMK KEY 9738-7095-6237-9690-2284
ADDRESS1 10, Fairfax Drive
ADDRESS2
ADDRESS3
POSTCODE S2 1SJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 76
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2020-03-17
LOCAL AUTHORITY E08000039
CONSTITUENCY E14001469
COUNTY
LODGEMENT DATE 2020-03-17
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 76
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 161
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 68
LIGHTING COST POTENTIAL 68
HEATING COST CURRENT 352
HEATING COST POTENTIAL 352
HOT WATER COST CURRENT 82
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 70
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 10, Fairfax Drive
LOCAL AUTHORITY LABEL Sheffield
CONSTITUENCY LABEL Sheffield Heeley
POSTTOWN SHEFFIELD
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2020-03-17 19:57:29
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100050967567
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000003
Address display
Nation ew